How can one film release nitric oxide quickly, then generate more?

A polymer film released stored nitric oxide when wet, then generated more from an added compound in a staged lab test relevant to medical-device surfaces.

Peer-Reviewed PaperStage · Prototype
Cutaway of a polymer film with nickel- and copper-based porous particles and gas cues for stored nitric oxide release and later generation.

Research Signal – Source date 2023-10-11

A thin polymer film made in a laboratory delivered nitric oxide in two ways: it released gas stored in one porous material when exposed to moisture, then generated additional nitric oxide from a molecule added to the test solution. The researchers measured both responses in controlled experiments. They did not test whether the film prevented infection or fouling on a medical device.

Nitric oxide is a gas with potential antibacterial uses. In this study, the first route produced a relatively large, brief release; the second produced a lower, continuing output under the assay conditions. The distinction matters because a fast initial release and later generation depend on different materials and different chemical conditions.

One film, two jobs for its porous particles

The researchers embedded porous particles in a thin, free-standing polyurethane film. The polymer served as the film matrix, while the particles supplied the nitric oxide functions. Across the compositions tested, the total amount of porous material stayed fixed at 10% of the polymer’s mass. What changed was the ratio of two metal-organic frameworks, or MOFs: porous structures built from metal ions and organic components.

CPO-27-Ni contains nickel. After activation and exposure to nitric oxide, it can hold the gas at open nickel sites. Moisture then triggers its release. CuBTTri contains copper and follows a different route: in the presence of S-nitrosoglutathione (GSNO), a molecule supplied to the test solution, it catalytically generates nitric oxide.

The researchers compared films containing only CPO-27-Ni, an equal mixture of the two MOFs, or only CuBTTri. In the moisture-triggered measurements, the film with 10% CPO-27-Ni released 1.2 millimoles of nitric oxide per gram of MOF. The equal mixture, with half as much CPO-27-Ni, released 0.54 millimoles per gram. The film with CuBTTri alone released just 0.01 millimoles per gram in that test.

The change follows the amount of the storage material in the film: less CPO-27-Ni meant less preloaded gas released. At 11% relative humidity, the CPO-27-Ni films first produced a burst, followed by slower release. The 10% and 5% versions returned to baseline after about 19.3 and 9.8 hours, respectively. CuBTTri alone showed negligible moisture-triggered release in the reported test.

The two routes also operated at different reported scales. The moisture-triggered release from CPO-27-Ni reached parts per million, while CuBTTri’s catalytic output from GSNO was measured at parts per billion. Those concentrations describe the laboratory measurements; they do not translate directly into a dose or an effect in a person.

Seeing where each material sits

A film containing two kinds of particles raises a structural question: are both materials actually dispersed through the polymer, and where are they relative to one another? The researchers used cryogenic scanning electron microscopy with elemental mapping to examine cross-sections. The technique freezes the sample for imaging and helped limit charging and beam damage that can complicate views of these materials.

Copper and nickel provided distinct markers. The copper map located CuBTTri particles, and the nickel map located CPO-27-Ni. In the equal-mixture film, the mapped particles were distributed through the polymer’s depth and did not significantly overlap. The measurements also estimated different particle sizes: about 3.45 micrometres for CuBTTri and 1.12 micrometres for CPO-27-Ni.

The team reconstructed a volume of roughly 960 cubic micrometres. That run took 1.5 hours, about six times faster than conventional focused ion beam scanning electron microscopy, according to the paper. The three-dimensional view matters independently of gas output: it provides a way to inspect how the two materials are arranged inside a composite, rather than inferring their positions from the film’s surface alone. The researchers also reported early work on image segmentation combined with machine learning, but the central result here is the ability to distinguish the two particle types in the film.

A staged test separated release from generation

To test whether the two functions could be observed in sequence, the researchers first activated the films, loaded them with nitric oxide, and submerged them in phosphate-buffered saline (PBS). The CPO-27-Ni-containing films released stored gas into the solution. With the samples fully submerged, that moisture-triggered release continued for about 2.4 hours in the 10% CPO-27-Ni film and 2.1 hours in the equal-mixture film.

After the measured nitric oxide level fell below about 10 parts per billion, the researchers added fresh PBS and GSNO. The fresh solution caused a brief spike across samples, attributed to the reaction-cell headspace being displaced and trapped gas being expelled. That transient spike is distinct from sustained catalytic generation.

After GSNO was added, the film with CPO-27-Ni alone did not show sustained nitric oxide production; its level continued to fall. Films containing CuBTTri generated nitric oxide above baseline at parts-per-billion levels. This staged sequence supports the interpretation that the film could first release previously stored gas and, after a separate chemical input, show the copper-based catalytic route.

It is a controlled assay, not a simulation of long-term use in a body. The sequence used a prepared solution and a later GSNO addition; it does not show that both phases would persist under the changing conditions around an implanted or indwelling device. Nor do gas measurements establish that bacteria attach less, that a device resists fouling, or that infections are reduced. The proposed antibacterial and antifouling uses remain possibilities for further testing.

What this could change

A dependable two-phase nitric oxide surface could eventually give a person using a long-term catheter a material designed to resist bacterial settlement soon after placement and during continued use. Catheters already exist; the possible new capability would be a surface that reliably provides both an early stored release and later gas generation. This film offers a laboratory starting point for that idea: it showed moisture-triggered release from CPO-27-Ni and GSNO-dependent generation from CuBTTri under separate stages of a controlled test.

Several independent requirements stand between that result and a useful device. The output would need to be biologically effective, remain within safe exposure levels, and have a sustained chemical supply for the later phase. A nearer measurable milestone would be a coated catheter segment tested under realistic flow, retaining both output phases while showing less bacterial attachment than an appropriate control. That would test device performance; it would still be distinct from showing a benefit for patients.