Why imagined hand movements are hard to turn into timely prosthetic commands

A 2025 review compares EEG and fNIRS for imagined-movement decoding and explains why an accurate score after a session may not mean timely prosthetic control.

Review or Meta-Analysis
A person imagines an open-hand movement as scalp electrodes and near-infrared sensors show separate paths toward a prosthetic hand.

Research Signal – Source date 2025-09-19

A brain–computer interface (BCI) aims to turn patterns of brain activity into commands for an external device. For someone who cannot move a missing hand, the command might begin with imagining that hand opening or closing. The idea is compelling because it could offer a route to control when actual movement, or the muscle signals commonly used by prostheses, is unavailable or inadequate. But a computer must recognize an imagined action from brain activity that can be faint, variable, and slow to interpret.

A review published on September 19, 2025, surveys research using electroencephalography (EEG), functional near-infrared spectroscopy (fNIRS), and combinations of the two to decode imagined and executed movements. It finds that online decoding of imagined movement is feasible, while remaining less reliable than decoding actual movement. Understanding why requires looking at what each sensor measures—and what researchers mean when they report a successful result.

Two sensors read different consequences of brain activity

EEG uses electrodes on the scalp to measure electrical activity. Because electrical changes can be captured quickly, EEG can follow the timing of brain activity associated with an intended movement. That speed matters when a system must distinguish one command from another and respond promptly. The tradeoff is that EEG is susceptible to electrical noise and movement artifacts, which can interfere with its readings, particularly outside controlled settings.

fNIRS uses near-infrared light. A light source and nearby detectors measure changes in oxygenated and deoxygenated blood in targeted brain regions. These blood-oxygenation changes are an indirect consequence of neural activity: the method tracks the body’s response to the brain’s demand for oxygen, rather than the fast electrical activity itself. fNIRS is less affected by some electrical and motion noise, but its physiological response takes time—about two seconds, according to the review. That delay complicates control that needs to feel immediate.

The two methods therefore offer complementary information. EEG can capture fast changes, while fNIRS provides a different view of activity through blood oxygenation. Combining them may help a classifier make sense of movement-related patterns that either sensor alone captures less reliably. The tradeoff is practical as well as scientific: a hybrid system requires more sensors and more computation.

An offline score is not a live command

The review separates experiments into offline and online designs. In an offline experiment, researchers collect brain signals and analyze them after the session. They have more freedom to process the data and compare classification methods without needing the system to act immediately. These studies are useful for developing algorithms and testing whether movement-related patterns can be distinguished in the recorded data.

Online experiments ask a different question. The system must process incoming signals, classify an intended movement, and provide feedback or control in real time. It has to do this quickly enough to be useful and reliably enough to tolerate noisy or changing signals. A high classification score calculated after the fact does not by itself show that a device could respond at the right moment during live use.

The review describes machine-learning methods that improved how well some studies sorted recorded signals by the movement a person imagined. Some were fast enough to be candidates for online use; live EEG studies also use simpler methods because each decision must be made quickly. The question is whether a system can recognize the imagined action when a command is needed, not only after the recording is analyzed.

Imagining a movement is its own challenge

Motor imagery means imagining a body movement without actually making it. Researchers have used imagined actions such as opening or closing a hand, flexing a wrist, or extending it as potential BCI commands. Imagery is useful for prosthetic control research because the user may not be able to perform the movement physically.

Yet imagined and executed movement do not produce equally easy signals to classify. The review describes stronger, clearer activation during actual movement. People can also find it difficult to imagine a movement consistently, and the amount of training needed varies between individuals. Fine actions involving the wrist or fingers can be especially challenging to decode because their brain activity involves a smaller area, while non-invasive sensors provide limited spatial detail.

Those differences help explain why results from executed movement cannot simply stand in for imagined movement. A system that recognizes a clear pattern while a participant moves a hand has not necessarily learned to identify the weaker, less repeatable pattern that accompanies imagining the same action. That biological difference shapes the task before the classifier even begins.

Hybrid promise meets a study-task mismatch

In principle, EEG and fNIRS could complement one another: EEG contributes timing information, and fNIRS contributes blood-oxygenation information about active brain regions. The review describes hybrid systems that improved movement classification by drawing on both modalities. But the mix of experiments matters. Many recent hybrid studies reviewed used actual movement rather than imagined movement alone. Actual movement provides clearer neural activity and stronger blood-flow responses, making it more straightforward to develop and test a system.

That leaves an important gap between showing that two sensors can work together during movement and showing that the same arrangement can reliably decode imagined hand actions. Imagery-based tasks are less represented in the reviewed hybrid work and pose the added challenges of weaker, more variable activity and greater training demands. The hybrid setup also adds computation and sensor-placement requirements. A useful combination on paper must still work as a responsive system for the people it is meant to serve.

What the review’s numbers can tell us

The review reports a search of PubMed and Web of Science for peer-reviewed articles published from January 2017 through September 2024, with additional studies identified through reference lists. Their search returned 604 records; after removing duplicates and studies that did not fit the review, 105 articles remained. The review groups findings by sensor type, movement task, and whether experiments were offline or online.

That range makes the review useful for seeing patterns across methods, but it also means the reported results come from different tasks, participants, sensors, and experimental designs. A percentage improvement in one classification study is not a general estimate of how well a prosthetic hand would perform. For example, the review describes one custom neural network whose reported accuracy improvement was 14.5% among 18 able-bodied participants and 11.2% among four amputees. Those figures illustrate a result in a particular study and sample; they do not establish a universal accuracy, user training requirement, or live prosthetic performance.

The review’s central progress is therefore methodological. Researchers have decoded imagined movement in offline and online experiments, explored machine-learning approaches, and tested ways to combine two different measurement types. Online imagined-movement decoding is possible in the studies surveyed, but it remains less reliable than decoding executed movement. The review does not validate a new prosthetic device or show improved day-to-day function for people with limb loss.

How this could shape the future

For a person with upper-limb loss, a dependable system that translates an imagined hand action into a timely prosthetic command could make it possible to choose an action by imagining it—for example, opening the hand before grasping a cup—when residual-muscle control is inadequate. Existing muscle-controlled prostheses already provide a way to control a limb; the additional capability would be dependable, timely control from imagined movement in ordinary use.

The review offers an early evidence bridge toward that possibility: studies have decoded imagined movements, and EEG-fNIRS combinations may draw on the speed of electrical measurement and the spatial information carried by blood-oxygenation changes. For that bridge to lead to useful control, the system would still need to work with appropriate hardware, support each user’s training needs, and be validated with the people it is intended to serve. One observable next milestone would be an online hybrid study with people with upper-limb loss that reports imagined hand-action accuracy and response time across repeated sessions. Such a result would help show whether the complementary sensors can support consistent, timely commands in the task that matters.

Key Sources

Keep exploring

More in this research area

Browse Health & Longevity →